Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
1/12
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP
1/12

Patient Monitor 12 Inch TFT Display Portable Vital Signs SpO2/NIBP/ECG/RESP/PR/TEMP

$349.99
$0.00
Save $-349.99
Free shipping
Quantity
Sku: 800001
Weight: 9kg
Barcode:
Features:    
  • Ergonomic & Portable: Designed for convenience in any healthcare environment.
  • Enhanced Display: 12" TFT display with configurable waveforms for optimal data visibility.
  • Reliable SPO2 Technology: Ensures accurate readings even during motion and low perfusion.
  • Interference Protection: Shielded against AC, high-frequency electrosurgical, and defibrillator interference.
  • Comprehensive Layout: Rich screen layout includes standard views, large fonts, trend graphs, OxyCRG, and more.
  • Extensive Data Storage: Store up to 720 hours of trends, 10,000 group NIBP, and 1,024 alarm events.
  • Advanced Analysis Tools: ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis, and calculation capabilities.
  • Customizable Alarms: Audible & visual alarms can be adjusted to suit individual preferences.
  • Efficient Patient Management: Simplified patient information management system.
  • Versatile Software: Supports various healthcare settings from NICU to standard patient rooms.
  • Seamless Upgrades: Easily upgrade software via USB for added functionality.
  • Networking Capabilities: Wired/wireless networking with central monitoring systems for up to 64 beds.
  • Integrated Recorder: Built-in 3 trace thermal recorder for printing real-time and historical data.
  • Multi-language Support: Offers language options including English, Spanish, Turkish, and more.
  • Long-lasting Battery Life: Super long life rechargeable Lithium battery ensures up to 4 hours of continuous operation.
  • Universal Compatibility: Suitable for monitoring adult, pediatric, and neonate patients.
Standard configuration:            
  • ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Optional:            
  • Dual TEMP
  • Dual IBP
  • ETCO2 (side stream) 
  • Thermal recorder
  • Wall mount
  • Trolley
Specification:
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
ST section 
Scope:     ±0.8mV
Precision :  < ±0.05mV
SpO2
Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 
NIBP 
Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute 
Temp
Single/double path 
Type:    Vascular/surface temperature 
Scope:    20℃~50℃
Accuracy:  ±0.2℃
Invasive blood pressure (optional)
Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV

Packing List:

 

 

Iitem

NO.

Content

Qty

Remark

Standard Configuration

1

Main Unit

1

 

2

Power cable                  

1

 

3

ECG Cable

1

Integrated

4

NIBP Cuff                     

1

Adult

5

External NIBP Hose                  

1

 

6

SPO2 Probe                          

1

 

7

Temperature Probe         

1

 

8

Disposable Electrodes                   

1

 

9

Packing List           

1

 

10

Grounding wire

1